{"id":"CVE-2007-1319","published":"2007-03-19T22:00:00Z","modified":"2024-08-07T12:50:34Z","title":"Unspecified vulnerability in the IOPCServer::RemoveGroup function in the OPCDA interface in Takebishi Electric…","vendor":null,"product":null,"tier":"tail","description":{"text":"Unspecified vulnerability in the IOPCServer::RemoveGroup function in the OPCDA interface in Takebishi Electric DeviceXPlorer OLE for Process Control (OPC) Server before 3.12 Build3 allows remote attackers to execute arbitrary code via unspecified vectors involving access to arbitrary memory. NOTE: this issue affects the (1) HIDIC, (2) MELSEC, (3) FA-M3, (4) MODBUS, and (5) SYSMAC OPC Servers.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.09121,"percentile":0.95428,"provenance":"source"},"cwes":[],"references":[{"url":"http://www.securityfocus.com/archive/1/463559/100/0/threaded","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://www.neutralbit.com/advisories/NB07-07.txt","tags":["x_refsource_MISC"]},{"url":"http://www.securityfocus.com/archive/1/463550/100/0/threaded","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://www.kb.cert.org/vuls/id/926551","tags":["third-party-advisory","x_refsource_CERT-VN"]},{"url":"http://www.neutralbit.com/advisories/NB07-17.txt","tags":["x_refsource_MISC"]},{"url":"http://www.faweb.net/us/opc/1231207.html","tags":["x_refsource_CONFIRM"]},{"url":"http://www.neutralbit.com/advisories/NB07-08.txt","tags":["x_refsource_MISC"]},{"url":"http://www.neutralbit.com/advisories/NB07-09.txt","tags":["x_refsource_MISC"]},{"url":"http://www.vupen.com/english/advisories/2007/1029","tags":["vdb-entry","x_refsource_VUPEN"]},{"url":"http://www.securityfocus.com/archive/1/463556/100/0/threaded","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://www.neutralbit.com/advisories/NB07-10.txt","tags":["x_refsource_MISC"]},{"url":"http://www.securityfocus.com/bid/23037","tags":["vdb-entry","x_refsource_BID"]},{"url":"http://secunia.com/advisories/24570","tags":["third-party-advisory","x_refsource_SECUNIA"]},{"url":"http://www.securityfocus.com/archive/1/463537/100/0/threaded","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://www.securityfocus.com/archive/1/463546/100/0/threaded","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://www.securitytracker.com/id?1017793","tags":["vdb-entry","x_refsource_SECTRACK"]}],"priority":{"score":19.1,"factors":[{"name":"EPSS percentile","points":19.09}]},"summary":{"text":"The flaw is an unspecified vulnerability in the IOPCServer::RemoveGroup function of the OPCDA interface in Takebishi Electric DeviceXPlorer OLE for Process Control (OPC) Server, affecting the HIDIC, MELSEC, FA-M3, MODBUS, and SYSMAC OPC Servers. An attacker who can reach the affected server remotely, via unspecified vectors involving access to arbitrary memory, may be able to execute arbitrary code.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T20:50:33Z"},"euvd":{"id":"EUVD-2007-1316","exploited":false,"provenance":"source"}}