{"id":"CVE-2014-5407","published":"2014-09-15T14:00:00Z","modified":"2025-11-03T18:52:21Z","title":"Schneider Electric VAMPSET Stack-based Buffer Overflow","vendor":"Schneider Electric","product":"VAMPSET","tier":"tail","description":{"text":"Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.1,"severity":"MEDIUM","version":"2.0","vector":"AV:L/AC:M/Au:S/C:P/I:P/A:P","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00371,"percentile":0.31857,"provenance":"source"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01","tags":["x_refsource_MISC"]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json","tags":[]},{"url":"http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/","tags":[]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01","tags":["x_refsource_MISC","x_transferred"]}],"priority":{"score":9.2,"factors":[{"name":"EPSS percentile","points":6.37},{"name":"CVSS severity","points":2.87}]},"vendorSlug":"schneider-electric","affectedVersions":[{"vendor":"Schneider Electric","product":"VAMPSET","versions":["<= 2.2.136"]}],"fixedVersions":[{"vendor":"Schneider Electric","product":"VAMPSET","versions":["2.2.145"]}],"solutions":{"items":["Schneider Electric released an update for distribution on August 21, 2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here: http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/ Schneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["To protect the computer and configuration files from unauthorized escalation of privileges through manipulation, Schneider Electric recommends users employ best IT practices to secure their computers and relay’s configuration files and to use User Access Control (UAC) to further improve the security of the computer. Additionally, to minimize the risk of attack, users who are not directly using this software on a regular basis are strongly encouraged to delete this application from their computer to reduce the likelihood of attack and to store relay configuration files in the client’s protected location."],"from":"CVE.org CNA","provenance":"source"},"euvd":{"id":"EUVD-2014-5295","exploited":false,"provenance":"source"}}