{"id":"CVE-2014-5412","published":"2014-09-18T10:00:00Z","modified":"2025-11-04T22:56:12Z","title":"Schneider Electric SCADA Expert ClearSCADA Improper Authentication","vendor":"Schneider Electric","product":"ClearSCADA","tier":"tail","description":{"text":"Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.4,"severity":"MEDIUM","version":"2.0","vector":"AV:N/AC:L/Au:N/C:P/I:P/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01572,"percentile":0.76006,"provenance":"source"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-259-01a","tags":[]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-259-01a.json","tags":[]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-259-01","tags":["x_refsource_MISC","x_transferred"]}],"priority":{"score":19.7,"factors":[{"name":"EPSS percentile","points":15.2},{"name":"CVSS severity","points":4.48}]},"vendorSlug":"schneider-electric","affectedVersions":[{"vendor":"Schneider Electric","product":"ClearSCADA","versions":["2010 R3 (build 72.4560)","2010 R3.1 (build 72.4644)"]},{"vendor":"Schneider Electric","product":"SCADA Expert ClearSCADA","versions":["2013 R1 (build 73.4729)","2013 R1.1 (build 73.4832)","2013 R1.1a (build 73.4903)","2013 R1.2 (build 73.4955)","2013 R2 (build 74.5094)","2013 R2.1 (build 74.5192)","2014 R1 (build 75.5210)"]}],"fixedVersions":[{"vendor":"Schneider Electric","product":"ClearSCADA","versions":["2010 R3.2"]},{"vendor":"Schneider Electric","product":"SCADA Expert ClearSCADA","versions":["2014 R1.1"]}],"solutions":{"items":["Schneider Electric advises all ClearSCADA users to take steps to secure the interfaces to the ClearSCADA system. The ClearSCADA database security configuration should be reviewed and updated to limit all system access to authorized users only. The access permissions of existing users should be reduced to only those required by their role (e.g., removing any higher level System Administration privileges from Operations or Engineering users), and specific accounts should be created with appropriate permissions for performing System Administration tasks. Existing ClearSCADA customers using WebX can protect their system from cross-site scripting attacks by disabling the “Allow database shutdown via WebX” option within the ClearSCADA Server Configuration utility. Existing ClearSCADA customers should take measures to ensure their system does not grant any system access until users have supplied a valid username and password. Schneider Electric has corrected the default user security permissions; however, upgrading an existing vulnerable installation to a new version will not affect existing configured database security permissions. Therefore, the measures suggested here are strongly…"],"from":"CVE.org CNA","provenance":"source"},"euvd":{"id":"EUVD-2014-5300","exploited":false,"provenance":"source"}}