{"id":"CVE-2014-9188","published":"2014-12-27T15:00:00Z","modified":"2025-07-24T22:39:42Z","title":"Schneider Electric ProClima Command Injection","vendor":"Schneider Electric","product":"ProClima","tier":"tail","description":{"text":"Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514.  NOTE: this may be clarified later based on details provided by researchers.","provenance":"source","from":"CVE.org"},"cvss":{"score":10,"severity":"CRITICAL","version":"2.0","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.06287,"percentile":0.93754,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01","tags":["x_refsource_CONFIRM"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-350-01","tags":[]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01","tags":["x_refsource_MISC","x_transferred"]}],"priority":{"score":25.8,"factors":[{"name":"EPSS percentile","points":18.75},{"name":"CVSS severity","points":7.0}]},"vendorSlug":"schneider-electric","affectedVersions":[{"vendor":"Schneider Electric","product":"ProClima","versions":["<= 6.0.1"]}],"solutions":{"items":["Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric’s web site at the following location: http://www.schneider-electric.com/ww/en/download/document/ProClima_software For further information on these vulnerabilities, please see Schneider Electric’s security notification (SEVD 2014-344-01) at Schneider Electric’s cybersecurity web page: http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page%20"],"from":"CVE.org CNA","provenance":"source"},"summary":{"text":"Schneider Electric ProClima contains a buffer overflow in the MDraw30.ocx ActiveX control. An attacker who can reach the product remotely, with no authentication needed, can exploit the flaw through unspecified vectors to run arbitrary code.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T05:39:30Z"},"euvd":{"id":"EUVD-2014-9013","exploited":false,"provenance":"source"}}