{"id":"CVE-2016-9158","published":"2016-12-17T03:34:00Z","modified":"2026-06-02T18:33:29Z","title":"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl.…","vendor":"Siemens","product":"SIMATIC S7-300 CPU family","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CISA ADP Vulnrichment"},"epss":{"score":0.03086,"percentile":0.88015,"provenance":"source"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"references":[{"url":"http://www.securityfocus.com/bid/94820","tags":["vdb-entry","x_refsource_BID"]},{"url":"http://www.securitytracker.com/id/1037434","tags":["vdb-entry","x_refsource_SECTRACK"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05","tags":["x_refsource_MISC"]},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf","tags":["x_refsource_CONFIRM"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf","tags":["x_refsource_MISC"]}],"priority":{"score":22.9,"factors":[{"name":"EPSS percentile","points":17.6},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens AG","product":"SIMATIC S7-300 CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 V6 and earlier CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 V7 CPU family","versions":["All versions"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2026-06-02T18:32:34.820675Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2016-9975","exploited":false,"provenance":"source"}}