{"id":"CVE-2016-9159","published":"2016-12-17T03:34:00Z","modified":"2026-06-02T20:14:08Z","title":"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl.…","vendor":"Siemens","product":"SIMATIC S7-300 CPU family","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.9,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","provenance":"source","from":"CISA ADP Vulnrichment"},"epss":{"score":0.01532,"percentile":0.7542,"provenance":"source"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"references":[{"url":"http://www.securityfocus.com/bid/94820","tags":["vdb-entry","x_refsource_BID"]},{"url":"http://www.securitytracker.com/id/1037434","tags":["vdb-entry","x_refsource_SECTRACK"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05","tags":["x_refsource_MISC"]},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf","tags":["x_refsource_CONFIRM"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf","tags":["x_refsource_MISC"]}],"priority":{"score":19.2,"factors":[{"name":"EPSS percentile","points":15.08},{"name":"CVSS severity","points":4.13}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens AG","product":"SIMATIC S7-300 CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 V6 and earlier CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-400 V7 CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-410 V8 CPU family","versions":["All versions"]},{"vendor":"Siemens AG","product":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","versions":["All versions"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-06-02T18:41:25.574831Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2016-9976","exploited":false,"provenance":"source"}}