{"id":"CVE-2017-8404","published":"2019-07-02T18:47:23Z","modified":"2024-08-05T16:34:23Z","title":"An issue was discovered on D-Link DCS-1130 devices","vendor":null,"product":null,"tier":"tail","description":{"text":"An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a \"system\" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library \"libmailutils.so\" is the one that has the vulnerable function \"sub_1FC4\" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter \"receiver1\" is extracted in function \"sub_15AC\" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in \"cgibox\" binary at address 0x0008F598 which calls the \"mailLoginTest\" function in \"libmailutils.so\" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.07667,"percentile":0.94723,"provenance":"source"},"cwes":[],"references":[{"url":"https://seclists.org/bugtraq/2019/Jun/8","tags":["mailing-list","x_refsource_BUGTRAQ"]},{"url":"http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html","tags":["x_refsource_MISC"]},{"url":"https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf","tags":["x_refsource_MISC"]}],"priority":{"score":23.9,"factors":[{"name":"EPSS percentile","points":18.94},{"name":"Public exploit code","points":5.0}]},"summary":{"text":"The command injection flaw lies in the D-Link DCS-1130 device's SMB folder and email settings, specifically in the mail login test functionality of the libmailutils.so library, where POST parameters are passed unsanitised to a system API call. An attacker able to send a crafted POST request to the device's mail credential test endpoint could inject operating system commands, with the details of the required access and authentication conditions not specified in the available information.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:58:51Z"},"euvd":{"id":"EUVD-2017-17356","exploited":false,"provenance":"source"},"exploitRefs":["http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"]}