{"id":"CVE-2018-11457","published":"2018-12-12T16:00:00Z","modified":"2024-08-05T08:10:14Z","title":"A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All…","vendor":"Siemens","product":"SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8","tier":"tail","description":{"text":"A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.04593,"percentile":0.91863,"provenance":"source"},"cwes":[{"id":"CWE-122","name":"Heap-based Buffer Overflow"}],"references":[{"url":"http://www.securityfocus.com/bid/106185","tags":["vdb-entry","x_refsource_BID"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf","tags":["x_refsource_CONFIRM"]}],"priority":{"score":18.4,"factors":[{"name":"EPSS percentile","points":18.37}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens AG","product":"SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8","versions":["SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1","SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5","SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"]}],"summary":{"text":"The integrated web server on port 4842/tcp of SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7 and SINUMERIK 840D sl V4.8 contains a heap-based buffer overflow. The flaw is exploitable only if port 4842/tcp has been manually opened in the firewall configuration of network port X130. A remote attacker with network access to the affected device on port 4842/tcp can send specially crafted requests to execute code with privileged permissions, requiring no privileges and no user interaction. Successful exploitation could compromise the confidentiality, integrity and availability of the web server.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T21:16:50Z"},"euvd":{"id":"EUVD-2018-3488","exploited":false,"provenance":"source"}}