{"id":"CVE-2019-5644","published":"2019-11-06T18:30:43Z","modified":"2024-09-16T22:41:06Z","title":"C4G BLIS Improper Access Control","vendor":"Computing For Good","product":"Basic Laboratory Information System","tier":"tail","description":{"text":"Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.","provenance":"source","from":"CVE.org"},"cvss":{"score":10,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0132,"percentile":0.7156,"provenance":"source"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"references":[{"url":"https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/","tags":["x_refsource_MISC"]}],"priority":{"score":21.3,"factors":[{"name":"EPSS percentile","points":14.31},{"name":"CVSS severity","points":7.0}]},"vendorSlug":"computing-for-good","affectedVersions":[{"vendor":"Computing For Good","product":"Basic Laboratory Information System","versions":[">= unspecified, <= 3.5"]}],"solutions":{"items":["C4G BLIS users should update to version 3.51 or later."],"from":"CVE.org CNA","provenance":"source"},"euvd":{"id":"EUVD-2019-15219","exploited":false,"provenance":"source"}}