{"id":"CVE-2020-15795","published":"2021-04-22T20:42:19Z","modified":"2024-08-04T13:30:21Z","title":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2…","vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","tier":"tail","description":{"text":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.1,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0659,"percentile":0.93994,"provenance":"source"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","tags":[]}],"priority":{"score":24.5,"factors":[{"name":"EPSS percentile","points":18.8},{"name":"CVSS severity","points":5.67}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Compact (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"Nucleus NET","versions":["All versions < V5.2"]},{"vendor":"Siemens","product":"Nucleus Source Code","versions":["Versions including affected DNS modules"]},{"vendor":"Siemens","product":"TALON TC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"TALON TC Modular (BACnet)","versions":["All versions < V3.5.5"]}],"summary":{"text":"The DNS domain name label parsing in the Nucleus NET and Nucleus Source Code DNS modules, as used in Siemens APOGEE PXC and TALON TC building automation controllers (BACnet and P2 Ethernet variants), fails to properly validate names in DNS responses. An attacker in a privileged network position who can send malformed DNS responses to an affected device, without authentication or user interaction, could trigger an out-of-bounds write to code execution in the current process or cause a denial of service.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:36:36Z"},"euvd":{"id":"EUVD-2020-7778","exploited":false,"provenance":"source"}}