{"id":"CVE-2020-15798","published":"2021-02-09T15:38:17Z","modified":"2026-06-02T18:59:33Z","title":"A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl","vendor":"Siemens","product":"SIMATIC HMI Comfort Panels (incl. SIPLUS variants)","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)","provenance":"source","from":"CVE.org"},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CISA ADP Vulnrichment"},"epss":{"score":0.05262,"percentile":0.92745,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf","tags":["x_refsource_MISC"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02","tags":["x_refsource_MISC"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf","tags":["x_refsource_CONFIRM"]}],"priority":{"score":25.4,"factors":[{"name":"EPSS percentile","points":18.55},{"name":"CVSS severity","points":6.86}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMATIC HMI Comfort Panels (incl. SIPLUS variants)","versions":["All versions < V16 Update 3a"]},{"vendor":"Siemens","product":"SIMATIC HMI KTP Mobile Panels","versions":["All versions < V16 Update 3a"]},{"vendor":"Siemens","product":"SINAMICS GH150","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS GL150 (with option X30)","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS GM150 (with option X30)","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS SH150","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS SL150","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS SM120","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS SM150","versions":["All versions"]},{"vendor":"Siemens","product":"SINAMICS SM150i","versions":["All versions"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2026-06-02T18:59:23.434500Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"Siemens SIMATIC HMI Comfort Panels (including SIPLUS variants) and KTP Mobile Panels before V16 Update 3a, along with several SINAMICS drive families (GH150, GL150, GM150, SH150, SL150, SM120, SM150, SM150i), contain a flaw in their telnet service, which does not require authentication when enabled. A remote attacker with network access and no credentials, and no user interaction, can gain full access to an affected device, with the telnet service enabled being the required configuration condition.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T07:23:47Z"},"euvd":{"id":"EUVD-2020-7781","exploited":false,"provenance":"source"}}