{"id":"CVE-2020-25176","published":"2022-03-18T18:00:31Z","modified":"2025-04-16T17:59:33Z","title":"Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal","vendor":"Rockwell Automation","product":"ISaGRAF Runtime","tier":"tail","description":{"text":"Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.1,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.06421,"percentile":0.93859,"provenance":"source"},"cwes":[{"id":"CWE-23","name":"Relative Path Traversal"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01","tags":["x_refsource_CONFIRM"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699","tags":["x_refsource_CONFIRM"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04","tags":["x_refsource_CONFIRM"]},{"url":"https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf","tags":["x_refsource_CONFIRM"]}],"priority":{"score":25.1,"factors":[{"name":"EPSS percentile","points":18.77},{"name":"CVSS severity","points":6.37}]},"vendorSlug":"rockwell-automation","affectedVersions":[{"vendor":"Rockwell Automation","product":"ISaGRAF Runtime","versions":["4.x","5.x"]}],"solutions":{"items":["Rockwell Automation recommends users update to ISaGRAF Runtime 5 Version 5.72.00. End users are encouraged to restrict or block access on TCP 1131 and TCP 1132 from outside the industrial control system. Confirm the least-privilege user principle is followed and user/service account access to Runtime's folder location is granted with a minimum amount of rights needed. Rockwell Automation recommends users of affected versions evaluate the mitigations provided and apply the appropriate mitigations to deployed products. Users are encouraged to combine this guidance with the general security guidelines for a comprehensive defense-in-depth strategy. To reduce risk, Rockwell Automation recommends users: Employ proper network segmentation and security controls. Minimize network exposure for all control system devices. Locate control systems behind firewalls. Isolate control systems from other networks when possible. Refer to the Converged Plantwide Ethernet (CPwE) Design and Implementation Guide for best practices deploying network segmentation and broader defense-in-depth strategies. Consider using proper network infrastructure controls, such as firewalls, UTM devices, VPN, or other…"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-04-16T17:30:56.007245Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The Rockwell Automation ISaGRAF Runtime contains a relative path traversal flaw in certain file operation commands of its eXchange Layer (IXL) protocol, because the parameter specifying the file name is not checked for reserved characters. An attacker with network access can exploit it without authenticating, requiring high privileges on the target's file handling to succeed, and no user interaction is needed.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:33:47Z"},"euvd":{"id":"EUVD-2020-17867","exploited":false,"provenance":"source"}}