{"id":"CVE-2020-27737","published":"2021-04-22T20:42:19Z","modified":"2024-08-04T16:18:45Z","title":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2…","vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","tier":"tail","description":{"text":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition  or leak the memory past the allocated structure.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.5,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0396,"percentile":0.90578,"provenance":"source"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","tags":[]}],"priority":{"score":22.7,"factors":[{"name":"EPSS percentile","points":18.12},{"name":"CVSS severity","points":4.55}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Compact (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"Nucleus NET","versions":["All versions"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V3","versions":["All versions < V2017.02.3"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V4","versions":["All versions < V4.1.0"]},{"vendor":"Siemens","product":"Nucleus Source Code","versions":["Versions including affected DNS modules"]},{"vendor":"Siemens","product":"SIMOTICS CONNECT 400","versions":["All versions < V0.5.0.0"]},{"vendor":"Siemens","product":"TALON TC Compact (BACnet)","versions":["All versions < V3.5.5"]}],"euvd":{"id":"EUVD-2020-20241","exploited":false,"provenance":"source"}}