{"id":"CVE-2020-28388","published":"2021-02-09T00:00:00Z","modified":"2026-06-02T20:14:56Z","title":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2…","vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","tier":"tail","description":{"text":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.5,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01367,"percentile":0.7253,"provenance":"source"},"cwes":[{"id":"CWE-342","name":"Predictable Exact Value from Previous Values"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","tags":[]}],"priority":{"score":19.1,"factors":[{"name":"EPSS percentile","points":14.51},{"name":"CVSS severity","points":4.55}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Compact (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"Nucleus NET","versions":["All versions < V5.2"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V3","versions":["All versions < V2012.12"]},{"vendor":"Siemens","product":"Nucleus Source Code","versions":["All versions"]},{"vendor":"Siemens","product":"PLUSCONTROL 1st Gen","versions":["All versions"]},{"vendor":"Siemens","product":"TALON TC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"TALON TC Modular (BACnet)","versions":["All versions < V3.5.5"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2026-06-02T19:29:04.600159Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2020-20847","exploited":false,"provenance":"source"}}