{"id":"CVE-2020-28392","published":"2021-02-09T15:38:20Z","modified":"2024-08-04T16:33:59Z","title":"A vulnerability has been identified in SIMARIS configuration (All versions < V4.0.1)","vendor":"Siemens","product":"SIMARIS configuration","tier":"tail","description":{"text":"A vulnerability has been identified in SIMARIS configuration (All versions < V4.0.1). During installation to default target folder, incorrect permissions are configured for the application folder and subfolders which could allow an attacker to gain persistence or potentially escalate privileges should a user with elevated credentials log onto the machine.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.00297,"percentile":0.22473,"provenance":"source"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-794542.pdf","tags":["x_refsource_MISC"]}],"priority":{"score":4.5,"factors":[{"name":"EPSS percentile","points":4.49}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMARIS configuration","versions":["All versions < V4.0.1"]}],"euvd":{"id":"EUVD-2020-20851","exploited":false,"provenance":"source"}}