{"id":"CVE-2020-5802","published":"2020-12-29T15:04:26Z","modified":"2024-08-04T08:39:25Z","title":"An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a…","vendor":null,"product":null,"tier":"tail","description":{"text":"An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.447,"percentile":0.98801,"provenance":"source"},"cwes":[],"references":[{"url":"https://www.tenable.com/security/research/tra-2020-71","tags":["x_refsource_CONFIRM"]}],"priority":{"score":19.8,"factors":[{"name":"EPSS percentile","points":19.76}]},"affectedVersions":[{"vendor":"n/a","product":"Rockwell FactoryTalk Linx","versions":["All versions of FactoryTalk Linx"]}],"summary":{"text":"The flaw lies in RnaDaSvr.dll, a component of FactoryTalk Linx (RSLinxNG.exe), where an attacker-controlled memory allocation size can be passed to the C++ new operator. An attacker who can reach TCP port 4241 on the affected system can send a specially crafted ConfigureItems message to trigger an unhandled exception that terminates RSLinxNG.exe, with no authentication or user interaction mentioned as required.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T20:36:35Z"},"euvd":{"id":"EUVD-2020-26959","exploited":false,"provenance":"source"}}