{"id":"CVE-2020-6087","published":"2020-10-14T12:35:08Z","modified":"2024-08-04T08:47:41Z","title":"An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of…","vendor":null,"product":null,"tier":"tail","description":{"text":"An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability If the ANSI Extended Symbol Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.0","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04263,"percentile":0.91302,"provenance":"source"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2020-1007","tags":["x_refsource_MISC"]}],"priority":{"score":23.5,"factors":[{"name":"EPSS percentile","points":18.26},{"name":"CVSS severity","points":5.25}]},"affectedVersions":[{"vendor":"n/a","product":"Allen Bradley","versions":["Allen-Bradley Flex IO 1794-AENT/B 4.003"]}],"summary":{"text":"The ENIP Request Path Data Segment handling in the Allen-Bradley Flex IO 1794-AENT/B device contains a flaw in which a supplied ANSI Extended Symbol Segment is treated as a data size in words without checking it against the remaining packet data, which is a buffer copy without a size check. A remote, unauthenticated attacker with network access can send a single crafted packet with no user interaction and no non-default configuration required, causing the device to enter a fault state that loses communications and requires a physical power cycle to recover.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:39:45Z"},"euvd":{"id":"EUVD-2020-27241","exploited":false,"provenance":"source"}}