{"id":"CVE-2021-25677","published":"2021-04-22T20:42:21Z","modified":"2024-08-03T20:11:28Z","title":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2…","vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","tier":"tail","description":{"text":"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01177,"percentile":0.67997,"provenance":"source"},"cwes":[{"id":"CWE-330","name":"Use of Insufficiently Random Values"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf","tags":[]}],"priority":{"score":17.3,"factors":[{"name":"EPSS percentile","points":13.6},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Compact (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (BACnet)","versions":["All versions < V3.5.5"]},{"vendor":"Siemens","product":"APOGEE PXC Modular (P2 Ethernet)","versions":["All versions < V2.8.20"]},{"vendor":"Siemens","product":"Nucleus NET","versions":["All versions"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V3","versions":["All versions < V2017.02.3"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V3","versions":["All versions < V2017.02.4"]},{"vendor":"Siemens","product":"Nucleus ReadyStart V4","versions":["All versions < V4.1.0"]},{"vendor":"Siemens","product":"Nucleus Source Code","versions":["Versions including affected DNS modules"]},{"vendor":"Siemens","product":"SIMOTICS CONNECT 400","versions":["All versions < V0.5.0.0"]}],"euvd":{"id":"EUVD-2021-12569","exploited":false,"provenance":"source"}}