{"id":"CVE-2021-26637","published":"2022-06-22T13:55:58Z","modified":"2024-08-03T20:26:25Z","title":"SiHAS Improper Authentication vulnerability","vendor":"Shina System Co.,Ltd","product":"SiHAS firmware","tier":"tail","description":{"text":"There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01945,"percentile":0.8044,"provenance":"source"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"references":[{"url":"https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66782","tags":["x_refsource_MISC"]}],"priority":{"score":22.2,"factors":[{"name":"EPSS percentile","points":16.09},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"shina-system","affectedVersions":[{"vendor":"Shina System Co.,Ltd","product":"SiHAS firmware","versions":["1.xx"]},{"vendor":"Shina System Co.,Ltd","product":"SiHAS old app","versions":["old app"]}],"euvd":{"id":"EUVD-2021-13431","exploited":false,"provenance":"source"}}