{"id":"CVE-2021-31892","published":"2021-07-13T11:02:55Z","modified":"2024-08-03T23:10:30Z","title":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance…","vendor":"Siemens","product":"SINUMERIK Analyse MyCondition","tier":"tail","description":{"text":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.00486,"percentile":0.34545,"provenance":"source"},"cwes":[{"id":"CWE-295","name":"Improper Certificate Validation"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","tags":["x_refsource_MISC"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","tags":["x_refsource_MISC"]}],"priority":{"score":6.9,"factors":[{"name":"EPSS percentile","points":6.91}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINUMERIK Analyse MyCondition","versions":["All versions"]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance","versions":["All versions"]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Monitor","versions":["All versions"]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Tuning","versions":["All versions"]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 02","versions":["All versions >= V02.00.12 < 02.00.18"]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 03","versions":["All versions >= V03.00.12 < 03.00.18"]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 04","versions":["V04.00.02 and all versions >= V04.00.15 < 04.00.18"]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 4.1","versions":["All versions < V4.1 SP10 HF3"]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 5.1","versions":["V5.1"]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines","versions":["All versions"]}],"euvd":{"id":"EUVD-2021-18767","exploited":false,"provenance":"source"}}