{"id":"CVE-2021-33733","published":"2021-10-12T09:49:33Z","modified":"2024-08-03T23:58:22Z","title":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1)","vendor":"Siemens","product":"SINEC NMS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.","provenance":"source","from":"CVE.org"},"cvss":null,"epss":{"score":0.15385,"percentile":0.96861,"provenance":"source"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","tags":["x_refsource_MISC"]}],"priority":{"score":19.4,"factors":[{"name":"EPSS percentile","points":19.37}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC NMS","versions":["All versions < V1.0 SP2 Update 1"]}],"summary":{"text":"A SQL injection flaw (CWE: improper neutralization of special elements in an SQL command) in Siemens SINEC NMS, affecting all versions before V1.0 SP2 Update 1, lives in the application's webserver component.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T20:45:23Z"},"euvd":{"id":"EUVD-2021-20410","exploited":false,"provenance":"source"}}