{"id":"CVE-2022-1367","published":"2022-05-02T18:02:31Z","modified":"2025-04-16T16:27:21Z","title":"Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in…","vendor":"Delta Electronics","product":"DIAEnergie","tier":"tail","description":{"text":"Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.19345,"percentile":0.97418,"provenance":"source"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01","tags":["x_refsource_CONFIRM"]}],"priority":{"score":26.3,"factors":[{"name":"EPSS percentile","points":19.48},{"name":"CVSS severity","points":6.86}]},"vendorSlug":"delta-electronics","affectedVersions":[{"vendor":"Delta Electronics","product":"DIAEnergie","versions":[">= unspecified, < 1.8.02.004"]}],"solutions":{"items":["Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["Delta also suggests users: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolate them from the business network. Use an application firewall that can detect attacks against “Path Traversal” and “SQL Injection” weakness. Never connect programming software to any network other than the network intended for that device. When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2025-04-16T15:55:51.447895Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The flaw is a blind SQL injection in the Handler_TCV.ashx component of Delta Electronics DIAEnergie, affecting all versions prior to 1.8.02.004. An attacker can exploit it over the network without authentication or user interaction, using low-complexity requests to inject arbitrary SQL queries that can read and modify database contents and execute system commands.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T05:38:42Z"},"euvd":{"id":"EUVD-2022-24687","exploited":false,"provenance":"source"}}