{"id":"CVE-2022-24282","published":"2022-03-08T00:00:00Z","modified":"2025-04-21T13:55:36Z","title":"A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3)…","vendor":"Siemens","product":"SINEC NMS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.2,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0143,"percentile":0.73677,"provenance":"source"},"cwes":[{"id":"CWE-502","name":"Deserialization of Untrusted Data"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-250085.pdf","tags":[]}],"priority":{"score":19.8,"factors":[{"name":"EPSS percentile","points":14.74},{"name":"CVSS severity","points":5.04}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC NMS","versions":["All versions >= V1.0.3 < V2.0"]},{"vendor":"Siemens","product":"SINEC NMS","versions":["All versions < V1.0.3"]},{"vendor":"Siemens","product":"SINEMA Server V14","versions":["All versions"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-04-18T15:23:44.796055Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-29186","exploited":false,"provenance":"source"}}