{"id":"CVE-2022-29223","published":"2022-05-24T14:25:10Z","modified":"2025-04-23T18:22:28Z","title":"Buffer overflow on HUB descriptor in Azure RTOS USBX","vendor":"azure-rtos","product":"usbx","tier":"tail","description":{"text":"Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack. In versions prior to 6.1.10, an attacker can cause a buffer overflow by providing the Azure RTOS USBX host stack a HUB descriptor with `bNbPorts` set to a value greater than `UX_MAX_TT` which defaults to 8. For a `bNbPorts` value of 255, the implementation of `ux_host_class_hub_descriptor_get` function will modify the contents of `hub` -> `ux_host_class_hub_device` -> `ux_device_hub_tt` array violating the end boundary by 255 - `UX_MAX_TT` items. The USB host stack needs to validate the number of ports reported by the hub, and if the value is larger than UX_MAX_TT, USB stack needs to reject the request. This fix has been included in USBX release 6.1.10.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01197,"percentile":0.67979,"provenance":"source"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"references":[{"url":"https://github.com/azure-rtos/usbx/security/advisories/GHSA-2qc5-385m-x862","tags":["x_refsource_CONFIRM"]},{"url":"https://github.com/azure-rtos/usbx/releases/tag/v6.1.10_rel","tags":["x_refsource_MISC"]}],"priority":{"score":18.8,"factors":[{"name":"EPSS percentile","points":13.6},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"azure-rtos","affectedVersions":[{"vendor":"azure-rtos","product":"usbx","versions":["< 6.1.10"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-04-23T15:54:45.954266Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-33585","exploited":false,"provenance":"source"}}