{"id":"CVE-2022-3353","published":"2023-02-21T13:50:46Z","modified":"2025-03-12T15:17:11Z","title":"IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products","vendor":"Hitachi Energy","product":"FOX61x TEGO1","tier":"tail","description":{"text":"\n\n\nA vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. \n\nAn attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections. \n\n\n\n\nAlready existing/established client-server connections are not affected.\n\n\n\n\n\nList of affected CPEs:\n\n\n\n\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*\n\n\n\n\n\n\n","provenance":"source","from":"CVE.org"},"cvss":{"score":5.9,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01105,"percentile":0.66588,"provenance":"source"},"cwes":[{"id":"CWE-404","name":"Improper Resource Shutdown or Release"}],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]}],"priority":{"score":17.4,"factors":[{"name":"EPSS percentile","points":13.32},{"name":"CVSS severity","points":4.13}]},"vendorSlug":"hitachi-energy","affectedVersions":[{"vendor":"Hitachi Energy","product":"FOX61x TEGO1","versions":["tego1_r15b08","tego1_r2a16_03","tego1_r2a16","tego1_r1e01","tego1_r1d02","tego1_r1c07","tego1_r1b02"]},{"vendor":"Hitachi Energy","product":"GMS600","versions":["GMS600 1.3"]},{"vendor":"Hitachi Energy","product":"ITT600 SA Explorer","versions":["ITT600 SA Explorer 1.1.0","ITT600 SA Explorer 1.1.1","ITT600 SA Explorer 1.1.2","ITT600 SA Explorer 1.5.0","ITT600 SA Explorer 1.5.1","ITT600 SA Explorer 1.6.0","ITT600 SA Explorer 1.6.0.1","ITT600 SA Explorer 1.7.0","ITT600 SA Explorer 1.7.2","ITT600 SA Explorer 1.8.0"]},{"vendor":"Hitachi Energy","product":"MicroSCADA X SYS600","versions":["SYS600 10","SYS600 10.1","SYS600 10.1.1","SYS600 10.2","SYS600 10.2.1","SYS600 10.3","SYS600 10.3.1","SYS600 10.4"]},{"vendor":"Hitachi Energy","product":"MSM","versions":["MSM 2.2.3;0"]},{"vendor":"Hitachi Energy","product":"PWC600","versions":["PWC600 1.0","PWC600 1.1","PWC600 1.2"]},{"vendor":"Hitachi Energy","product":"REB500","versions":[">= REB500 7.0, < 7.*",">= REB500 8.0, < 8.*"]},{"vendor":"Hitachi Energy","product":"Relion® 670","versions":["Relion 670 1.2","Relion 670 2.0","Relion 670 version 2.1","Relion 670 2.2.0","Relion 670 2.2.1","Relion 670 2.2.2","Relion 670 2.2.3","Relion 670 2.2.4","Relion 670 2.2.5"]},{"vendor":"Hitachi Energy","product":"Relion® 650","versions":["Relion 650 1.1","Relion 650 1.3","Relion 650 2.1","Relion 650 2.2.0","Relion 650 2.2.1","Relion 650 2.2.2","Relion 650 2.2.3","Relion 650 2.2.4","Relion 650 2.2.5"]},{"vendor":"Hitachi Energy","product":"SAM600-IO","versions":["Relion SAM600-IO 2.2.1","Relion SAM600-IO 2.2.5"]}],"fixedVersions":[{"vendor":"Hitachi Energy","product":"FOX61x TEGO1","versions":["tego1_r16a11"]},{"vendor":"Hitachi Energy","product":"ITT600 SA Explorer","versions":["ITT600 SA Explorer 2.1.1.2"]},{"vendor":"Hitachi Energy","product":"MicroSCADA X SYS600","versions":["SYS600 10.4.1"]},{"vendor":"Hitachi Energy","product":"REB500","versions":["REB500 8.3.3.0"]},{"vendor":"Hitachi Energy","product":"RTU500","versions":["RTU500 12.0.15","RTU500 12.2.12","RTU500 12.4.12","RTU500 12.6.9","RTU500 12.7.5","RTU500 13.2.6"]}],"solutions":{"items":["Upgrade the system once remediated version is available."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."],"from":"CVE.org CNA","provenance":"source"},"capec":[{"id":"CAPEC-130","name":"Excessive Allocation"}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-03-12T15:16:44.962103Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-42738","exploited":false,"provenance":"source"}}