{"id":"CVE-2022-3686","published":"2023-03-28T12:57:11Z","modified":"2025-02-18T20:25:39Z","title":"SDM600 API permission check","vendor":"Hitachi Energy","product":"SDM600","tier":"tail","description":{"text":"A vulnerability exists in a SDM600 endpoint.\nAn attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.\nThis issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)\n\n \n\nList of CPEs:\n\n\n  *  cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*\n\n\n","provenance":"source","from":"CVE.org"},"cvss":{"score":4.8,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01442,"percentile":0.73881,"provenance":"source"},"cwes":[{"id":"CWE-285","name":"Improper Authorization"}],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000138&LanguageCode=en&DocumentPartId=&Action=Launch","tags":[]}],"priority":{"score":18.1,"factors":[{"name":"EPSS percentile","points":14.78},{"name":"CVSS severity","points":3.36}]},"vendorSlug":"hitachi-energy","affectedVersions":[{"vendor":"Hitachi Energy","product":"SDM600","versions":[">= SDM600 1.2, <= SDM600 1.2.*",">= SDM600 1.1, <= SDM600 1.1.*",">= SDM600 1.0, <= SDM600 1.0.*"]}],"fixedVersions":[{"vendor":"Hitachi Energy","product":"SDM600","versions":["SDM600 1.3"]}],"solutions":{"items":["The vulnerability is remediated in SDM600 1.3.0.1339. Please update to SDM600 1.3.0.1339 version or apply mitigation as described in the Mitigation Factors/Workarounds Section."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["Apply mitigation as described in the cybersecurity advisory Mitigation Factors/Workarounds Section."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-02-18T20:25:28.136869Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-43045","exploited":false,"provenance":"source"}}