{"id":"CVE-2022-42970","published":"2023-02-01T00:00:00Z","modified":"2025-02-05T20:17:08Z","title":"A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for…","vendor":"Schneider Electric","product":"APC Easy UPS Online Monitoring Software","tier":"tail","description":{"text":"A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)","provenance":"source","from":"CVE.org"},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00737,"percentile":0.55429,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf","tags":[]}],"priority":{"score":17.9,"factors":[{"name":"EPSS percentile","points":11.09},{"name":"CVSS severity","points":6.86}]},"vendorSlug":"schneider-electric","affectedVersions":[{"vendor":"Schneider Electric","product":"APC Easy UPS Online Monitoring Software","versions":[">= Windows 7, 10, 11 Windows Server 2016, 2019, 2022, < V2.5-GA"]},{"vendor":"Schneider Electric","product":"APC Easy UPS Online Monitoring Software","versions":[">= (Windows 11, Windows Server 2019, 2022, < V2.5-GA-01-22261"]},{"vendor":"Schneider Electric","product":"Schneider Electric Easy UPS Online Monitoring Software","versions":[">= Windows 7, 10, 11 Windows Server 2016, 2019, 2022, < V2.5-GS"]},{"vendor":"Schneider Electric","product":"Schneider Electric Easy UPS Online Monitoring Software","versions":[">= Windows 11, Windows Server 2019, 2022, < V2.5-GS-01-22261"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2025-02-05T19:56:37.171973Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-46020","exploited":false,"provenance":"source"}}