{"id":"CVE-2022-43546","published":"2022-11-08T00:00:00Z","modified":"2024-10-21T16:08:33Z","title":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All…","vendor":"Siemens","product":"POWER METER SICAM Q100","tier":"tail","description":{"text":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the EndTime-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.9,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0208,"percentile":0.81981,"provenance":"source"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-572005.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf","tags":[]}],"priority":{"score":23.3,"factors":[{"name":"EPSS percentile","points":16.4},{"name":"CVSS severity","points":6.93}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"POWER METER SICAM Q100","versions":["All versions < V2.50"]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","versions":["All versions < V2.50"]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","versions":["All versions < V2.50"]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","versions":["All versions < V2.50"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]},{"vendor":"Siemens","product":"SICAM P850","versions":["All versions < V3.10"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-10-15T17:16:01.044378Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2022-46543","exploited":false,"provenance":"source"}}