{"id":"CVE-2023-0754","published":"2023-02-23T21:27:09Z","modified":"2025-01-16T21:55:46Z","title":"The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the…","vendor":"PTC","product":"ThingWorx Edge C-SDK","tier":"tail","description":{"text":"\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could  allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n","provenance":"source","from":"CVE.org"},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.02937,"percentile":0.87436,"provenance":"source"},"cwes":[{"id":"CWE-190","name":"Integer Overflow or Wraparound"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01","tags":[]}],"priority":{"score":24.3,"factors":[{"name":"EPSS percentile","points":17.49},{"name":"CVSS severity","points":6.86}]},"vendorSlug":"ptc","affectedVersions":[{"vendor":"PTC","product":"ThingWorx Edge C-SDK","versions":["<= v2.2.12.1052 "]},{"vendor":"Microsoft","product":".NET-SDK","versions":["<= v5.8.4.971 "]},{"vendor":"PTC","product":"ThingWorx Edge MicroServer (EMS)","versions":["<= v5.4.10.0 "]},{"vendor":"PTC","product":"Kepware KEPServerEX","versions":["<= v6.12 "]},{"vendor":"PTC","product":"ThingWorx Kepware Server ","versions":["<= v6.12 "]},{"vendor":"PTC","product":"ThingWorx Industrial Connectivity","versions":["All Versions"]},{"vendor":"PTC","product":"ThingWorx Kepware Edge","versions":["<= v1.5"]},{"vendor":"Rockwell Automation ","product":"KEPServer Enterprise ","versions":["<= v6.12"]},{"vendor":"General Electric ","product":"Digital Industrial Gateway Server ","versions":["<= v7.612"]}],"solutions":{"items":["PTC has released the following resolutions: Update the impacted product to the latest version: · ThingWorx Edge C-SDK: 3.0.0 or later. · ThingWorx Edge MicroServer (EMS): v5.4.11 or later. · .NET-SDK: v5.8.5 or later. For Kepware products, the vulnerability is mitigated if the ThingWorx Interface is not enabled. To use the ThingWorx Interface without the vulnerability, update to the latest version of the product: · Kepware KEPServerEX: v6.13 or later. · ThingWorx Kepware Server (formerly ThingWorx Industrial Connectivity): v6.13 or later. · ThingWorx Kepware Edge: v1.6 or later. The following products should be upgraded as indicated or in accordance with the applicable organization’s recommendations if the ThingWorx Interface is in use: · Rockwell Automation KEPServer Enterprise: v6.13 or later. · GE Digital Industrial Gateway Server: v7.613 or later. For more information see PTC’s Customer Support Article ."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2025-01-16T20:59:05.493845Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-12772","exploited":false,"provenance":"source"}}