{"id":"CVE-2023-1134","published":"2023-03-27T14:47:43Z","modified":"2025-01-16T21:39:42Z","title":"CVE-2023-1134","vendor":"Delta Electronics","product":"InfraSuite Device Master","tier":"tail","description":{"text":"Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.1,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00836,"percentile":0.54996,"provenance":"source"},"cwes":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02","tags":[]}],"priority":{"score":16.0,"factors":[{"name":"EPSS percentile","points":11.0},{"name":"CVSS severity","points":4.97}]},"vendorSlug":"delta-electronics","affectedVersions":[{"vendor":"Delta Electronics","product":"InfraSuite Device Master","versions":["< 1.0.5"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-01-16T20:21:41.926690Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-23417","exploited":false,"provenance":"source"}}