{"id":"CVE-2023-23449","published":"2023-05-15T10:54:46Z","modified":"2026-06-01T12:21:55Z","title":"Observable Response Discrepancy in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114…","vendor":"SICK AG","product":"SICK FTMG-ESD15AXX AIR FLOW SENSOR","tier":"tail","description":{"text":"Observable Response Discrepancy in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker\nto gain information about valid usernames by analyzing challenge responses from the server via the\nREST interface.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00785,"percentile":0.56995,"provenance":"source"},"cwes":[{"id":"CWE-204","name":"Observable Response Discrepancy"}],"references":[{"url":"https://sick.com/psirt","tags":["issue-tracking"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf","tags":["vendor-advisory"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json","tags":["x_csaf"]}],"priority":{"score":15.1,"factors":[{"name":"EPSS percentile","points":11.4},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"sick","affectedVersions":[{"vendor":"SICK AG","product":"SICK FTMG-ESD15AXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESD20AXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESD25AXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESN40SXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESN50SXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESR40SXX AIR FLOW SENSOR","versions":["all firmware versions"]},{"vendor":"SICK AG","product":"SICK FTMG-ESR50SXX AIR FLOW SENSOR","versions":["all firmware versions"]}],"workarounds":{"items":["Please make sure that you apply general security practices when operating the SICK FTMg like network segmentation. The following General Security Practices and Operating Guidelines could mitigate the associated security risk."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-01-23T19:13:50.768926Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-27549","exploited":false,"provenance":"source"}}