{"id":"CVE-2023-24512","published":"2023-04-25T00:00:00Z","modified":"2025-02-03T19:15:59Z","title":"On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft…","vendor":"Arista Networks","product":"Terminattr","tier":"tail","description":{"text":"On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00598,"percentile":0.49528,"provenance":"source"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"references":[{"url":"https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086","tags":[]}],"priority":{"score":16.1,"factors":[{"name":"EPSS percentile","points":9.91},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"arista","affectedVersions":[{"vendor":"Arista Networks","product":"Terminattr","versions":["1.23.0",">= unspecified, <= 1.19.5",">= 1.24.0, <= 1.24.3",">= 1.22.0, <= 1.22.1"]}],"solutions":{"items":["While the steps listed above resolve the issue, the recommended long term solution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. There are two possible solutions: Upgrade the Streaming Telemetry Agent Customers can upgrade the Streaming Telemetry Agent to a fixed version, following the directions in https://arista.my.site.com/AristaCommunity/s/article/terminattr-upgrade-downgrade. Fixes are available in the following supported release trains: TerminAttr 1.25.0 and later Terminattr versions Users of 1.24.X and 1.23.X TerminAttr releases should upgrade to TerminAttr 1.25.0 or later. TerminAttr 1.22.2 and later version in the TerminAttr 1.22.X train TerminAttr 1.19.6 and later versions in the TerminAttr 1.19.X train","Upgrade EOS Customers can upgrade to a version of EOS which contains a fixed version of the Streaming Telemetry Agent within the EOS image, as documented in https://www.arista.com/en/um-eos/eos-upgradedowngrade-overview: EOS 4.29.2F and later releases, which contains TerminAttr 1.25.0 or a more recent version EOS 4.28.6M and later releases in the 4.28.X train, which contains TerminAttr 1.22.2 or a more recent version EOS 4.27.9M and later releases in the 4.27.X train, which contains TerminAttr 1.19.6 or a more recent version EOS 4.26.10M and later releases in the 4.26.X train, which contains TerminAttr 1.19.6 or a more recent version"],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["The streaming telemetry agent can be configured in gRPC read-only mode by specifying -grpcreadonly as part of its configuration. For instance as follows: switch# daemon TerminAttr exec /usr/bin/TerminAttr -grpcreadonly -grpcaddr=... <other options...> no shutdown If TerminAttr is running, it must be restarted for the configuration to take effect. This can be done as follows: switch# daemon TerminAttr shutdown wait-for-warmup no shutdown"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-02-03T19:15:55.595547Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-28530","exploited":false,"provenance":"source"}}