{"id":"CVE-2023-24548","published":"2023-08-29T16:13:10Z","modified":"2024-09-30T17:46:19Z","title":"On affected platforms running Arista EOS with VXLAN configured, malformed or truncated packets received over a VXLAN…","vendor":"Arista Networks","product":"EOS","tier":"tail","description":{"text":"On affected platforms running Arista EOS with VXLAN configured, malformed or truncated packets received over a VXLAN tunnel and forwarded in hardware can cause egress ports to be unable to forward packets. The device will continue to be susceptible to the issue until remediation is in place.\n","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00478,"percentile":0.42163,"provenance":"source"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"references":[{"url":"https://www.arista.com/en/support/advisories-notices/security-advisory/18043-security-advisory-0089","tags":[]}],"priority":{"score":12.1,"factors":[{"name":"EPSS percentile","points":8.43},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"arista","affectedVersions":[{"vendor":"Arista Networks","product":"EOS","versions":[">= 4.25.0F, <= =4.25.0F",">= 4.24.0, <= <=4.24.11M",">= 4.23.0, <= <=4.23.14M",">= 4.22.1F, <= <=4.22.13M"]}],"solutions":{"items":["The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades CVE-2023-24548 has been fixed in the following releases: * 4.30.0F and later releases in the 4.30.x train * 4.29.0F and later releases in the 4.29.x train * 4.28.0F and later releases in the 4.28.x train * 4.27.0F and later releases in the 4.27.x train * 4.26.0F and later releases in the 4.26.x train * 4.25.1F and later releases in the 4.25.x train No remediation is planned for EOS software versions that are beyond their standard EOS support lifecycle https://www.arista.com/en/support/product-documentation/eos-life-cycle-policy (i.e. 4.22, 4.23)."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["There is no known mitigation for the issue. The recommended resolution is to upgrade to a remediated software version at your earliest convenience."],"from":"CVE.org CNA","provenance":"source"},"capec":[{"id":"CAPEC-583","name":"Disabling Network Hardware"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2024-09-30T17:34:44.954023Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-28564","exploited":false,"provenance":"source"}}