{"id":"CVE-2023-30756","published":"2024-09-10T09:33:40Z","modified":"2024-09-10T15:10:00Z","title":"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl","vendor":"Siemens","product":"SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.\r\n\r\nThis could allow a remote attacker with no privileges to cause a denial of service condition in the system.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.9,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00453,"percentile":0.40228,"provenance":"source"},"cwes":[{"id":"CWE-476","name":"NULL Pointer Dereference"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-423808.html","tags":[]}],"priority":{"score":12.2,"factors":[{"name":"EPSS percentile","points":8.05},{"name":"CVSS severity","points":4.13}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 (incl. SIPLUS variants)","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","versions":["< V3.5.20"]},{"vendor":"Siemens","product":"SIMATIC HMI Comfort Panels (incl. SIPLUS variants)","versions":["All versions"]},{"vendor":"Siemens","product":"SIMATIC IPC DiagBase","versions":["all versions"]},{"vendor":"Siemens","product":"SIMATIC IPC DiagMonitor","versions":["All versions"]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Advanced","versions":["All versions"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2024-09-10T15:09:52.396615Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-35120","exploited":false,"provenance":"source"}}