{"id":"CVE-2023-36749","published":"2023-07-11T09:07:15Z","modified":"2024-11-27T14:15:10Z","title":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All…","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","tier":"tail","description":{"text":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The webserver of the affected devices support insecure TLS 1.0 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.4,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00292,"percentile":0.22275,"provenance":"source"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf","tags":[]}],"priority":{"score":9.6,"factors":[{"name":"EPSS percentile","points":4.46},{"name":"CVSS severity","points":5.18}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","versions":["All versions < V2.16.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","versions":["All versions < V2.16.0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-11-27T13:57:48.336400Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-40692","exploited":false,"provenance":"source"}}