{"id":"CVE-2023-38071","published":"2023-09-12T09:32:14Z","modified":"2024-11-25T21:17:56Z","title":"A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions…","vendor":"Siemens","product":"JT2Go","tier":"tail","description":{"text":"A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00326,"percentile":0.18144,"provenance":"source"},"cwes":[{"id":"CWE-122","name":"Heap-based Buffer Overflow"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf","tags":[]}],"priority":{"score":9.1,"factors":[{"name":"EPSS percentile","points":3.63},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"JT2Go","versions":["All versions < V14.3.0.1"]},{"vendor":"Siemens","product":"Teamcenter Visualization V13.3","versions":["All versions < V13.3.0.12"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.0","versions":["All versions"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.1","versions":["All versions < V14.1.0.11"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":["All versions < V14.2.0.6"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":["All versions < V14.3.0.1"]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","versions":["All versions < V2201.0010"]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","versions":["All versions < V2302.0004"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-11-25T21:17:44.338467Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-41897","exploited":false,"provenance":"source"}}