{"id":"CVE-2023-38683","published":"2023-08-08T09:20:48Z","modified":"2024-10-11T13:16:08Z","title":"A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions…","vendor":"Siemens","product":"JT2Go","tier":"tail","description":{"text":"A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted TIFF file. This could allow an attacker to execute code in the context of the current process.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00311,"percentile":0.24583,"provenance":"source"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf","tags":[]}],"priority":{"score":10.4,"factors":[{"name":"EPSS percentile","points":4.92},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"JT2Go","versions":["All versions < V14.2.0.5"]},{"vendor":"Siemens","product":"Teamcenter Visualization V13.2","versions":["All versions < V13.2.0.14"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.1","versions":["All versions < V14.1.0.10"]},{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":["All versions < V14.2.0.5"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-10-11T13:15:58.316782Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-42471","exploited":false,"provenance":"source"}}