{"id":"CVE-2023-47279","published":"2023-11-30T22:12:05Z","modified":"2025-06-03T13:44:50Z","title":"Delta Electronics InfraSuite Device Master Path Traversal","vendor":"Delta Electronics","product":"InfraSuite Device Master","tier":"tail","description":{"text":"In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0092,"percentile":0.58508,"provenance":"source"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01","tags":[]}],"priority":{"score":17.0,"factors":[{"name":"EPSS percentile","points":11.7},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"delta-electronics","affectedVersions":[{"vendor":"Delta Electronics","product":"InfraSuite Device Master","versions":["<= 1.0.7"]}],"solutions":{"items":["Delta Electronics recommends updating their software to v1.0.10 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.10.exe  or later."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-06-03T13:44:37.906887Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-51409","exploited":false,"provenance":"source"}}