{"id":"CVE-2023-52891","published":"2024-07-09T12:04:42Z","modified":"2025-08-27T20:42:53Z","title":"A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO…","vendor":"Siemens","product":"SIMATIC Energy Manager Basic","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00465,"percentile":0.41173,"provenance":"source"},"cwes":[{"id":"CWE-1325","name":"Improperly Controlled Sequential Memory Allocation"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-088132.html","tags":[]}],"priority":{"score":11.9,"factors":[{"name":"EPSS percentile","points":8.23},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMATIC Energy Manager Basic","versions":["< V7.5"]},{"vendor":"Siemens","product":"SIMATIC Energy Manager PRO","versions":["< V7.5"]},{"vendor":"Siemens","product":"SIMATIC IPC DiagBase","versions":["all versions"]},{"vendor":"Siemens","product":"SIMATIC IPC DiagMonitor","versions":["all versions"]},{"vendor":"Siemens","product":"SIMIT V10","versions":["all versions"]},{"vendor":"Siemens","product":"SIMIT V11","versions":["< V11.1"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2024-07-09T13:26:14.481281Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2023-59603","exploited":false,"provenance":"source"},"lineage":{"parents":[{"from":"CVE-2023-27321","to":"CVE-2023-52891","relation":"related","confidence":"low","kind":"lineage","evidence":[{"kind":"text","provenance":"source","relation":"related","quote":"Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation.","from":"CVE.org","in":"CVE-2023-52891"}]}]}}