{"id":"CVE-2024-11046","published":"2024-11-10T03:00:10Z","modified":"2024-11-12T15:05:58Z","title":"D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp os command injection","vendor":"D-Link","product":"DI-8003","tier":"tail","description":{"text":"A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been classified as critical. Affected is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04371,"percentile":0.91493,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.283632","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.283632","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.434929","tags":["third-party-advisory"]},{"url":"https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_command_injection/DI8003_command_injection.md","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"priority":{"score":27.7,"factors":[{"name":"EPSS percentile","points":18.3},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"d-link","affectedVersions":[{"vendor":"D-Link","product":"DI-8003","versions":["16.07.16A1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-12T15:05:44.291252Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the upgrade_filter_asp function of /upgrade_filter.asp in the D-Link DI-8003 (firmware 16.07.16A1), where the path argument is not properly neutralised before being passed to an OS command. An attacker with low-privilege authenticated access can exploit this remotely over the network without any user interaction, and the impact is limited to partial loss of confidentiality, integrity and availability.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:44Z"},"euvd":{"id":"EUVD-2024-33616","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_command_injection/DI8003_command_injection.md"]}