{"id":"CVE-2024-11653","published":"2024-11-25T03:31:30Z","modified":"2024-11-26T15:51:27Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been rated as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_traceroute. The manipulation of the argument diag_traceroute leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.29105,"percentile":0.98209,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285974","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285974","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446633","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/AHPnwdCaoiaQ3fkrdeUcqPfLnEd","tags":["exploit"]}],"priority":{"score":27.9,"factors":[{"name":"EPSS percentile","points":19.64},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-26T15:50:10.516398Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The flaw is a command injection vulnerability in the diag_traceroute functionality (the /admin/network/diag_traceroute file) of EnGenius ENH1350EXT, ENS500-AC and ENS620EXT devices, where the diag_traceroute argument is not properly sanitised. An attacker with high privileges (authenticated administrative access) can remotely inject operating system commands through that argument, with no user interaction required and no particular network configuration needed beyond reaching the device's management interface.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:25Z"},"euvd":{"id":"EUVD-2024-33931","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/AHPnwdCaoiaQ3fkrdeUcqPfLnEd"]}