{"id":"CVE-2024-11654","published":"2024-11-25T04:00:27Z","modified":"2024-11-26T15:48:44Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute6 command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This affects an unknown part of the file /admin/network/diag_traceroute6. The manipulation of the argument diag_traceroute6 leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.15934,"percentile":0.97521,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285975","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285975","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446637","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/YrKfwHqLjijPeYkMTQfcdhrBnyg?from=from_copylink","tags":["exploit"]}],"priority":{"score":27.8,"factors":[{"name":"EPSS percentile","points":19.5},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-26T15:47:42.788674Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The EnGenius ENH1350EXT, ENS500-AC and ENS620EXT devices contain a command injection flaw in the diag_traceroute6 argument of the /admin/network/diag_traceroute6 component, affecting versions up to 20241118. An attacker can exploit it remotely by supplying crafted input to that argument, which requires high privileges (PR:H), with no user interaction needed.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:25Z"},"euvd":{"id":"EUVD-2024-33932","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/YrKfwHqLjijPeYkMTQfcdhrBnyg?from=from_copylink"]}