{"id":"CVE-2024-11655","published":"2024-11-25T04:31:23Z","modified":"2024-11-26T15:46:43Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_pinginterface command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability classified as critical was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This vulnerability affects unknown code of the file /admin/network/diag_pinginterface. The manipulation of the argument diag_ping leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.28766,"percentile":0.98191,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285976","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285976","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446638","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/PpM6w3TF8ilK3Ek5RLqcLPUrn6c","tags":["exploit"]}],"priority":{"score":27.9,"factors":[{"name":"EPSS percentile","points":19.64},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-26T15:45:50.846810Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The flaw is a command injection vulnerability in the diag_pinginterface component (/admin/network/diag_pinginterface) of the EnGenius ENH1350EXT, ENS500-AC and ENS620EXT products, where the diag_ping argument is not properly neutralised. An attacker with high privileges can exploit it remotely over the network, without user interaction, to inject and run operating system commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:25Z"},"euvd":{"id":"EUVD-2024-33933","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/PpM6w3TF8ilK3Ek5RLqcLPUrn6c"]}