{"id":"CVE-2024-11656","published":"2024-11-25T05:00:28Z","modified":"2024-11-26T15:45:02Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_ping6 command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability, which was classified as critical, has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This issue affects some unknown processing of the file /admin/network/diag_ping6. The manipulation of the argument diag_ping6 leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.28766,"percentile":0.9819,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285977","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285977","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446639","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/FBJCwjFPZiY4aakElh6cwF25nff","tags":["exploit"]}],"priority":{"score":27.9,"factors":[{"name":"EPSS percentile","points":19.64},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-26T15:43:37.081034Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The flaw is a command injection vulnerability in the diag_ping6 argument of the /admin/network/diag_ping6 file in the EnGenius ENH1350EXT, ENS500-AC and ENS620EXT products. An attacker who can reach the device over the network and holds high-privilege credentials can inject operating system commands through that argument, and the attack requires no user interaction.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:26Z"},"euvd":{"id":"EUVD-2024-33934","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/FBJCwjFPZiY4aakElh6cwF25nff"]}