{"id":"CVE-2024-11657","published":"2024-11-25T05:31:25Z","modified":"2024-11-26T15:25:02Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_nslookup command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability, which was classified as critical, was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. Affected is an unknown function of the file /admin/network/diag_nslookup. The manipulation of the argument diag_nslookup leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.29105,"percentile":0.98208,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285978","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285978","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446640","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/RURswTkepiuKCzkGMd2cA1M2nNc","tags":["exploit"]}],"priority":{"score":27.9,"factors":[{"name":"EPSS percentile","points":19.64},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-26T15:22:48.351621Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The command injection flaw lies in the diag_nslookup argument handling of the /admin/network/diag_nslookup function in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT devices, affecting releases up to 20241118. An attacker can inject operating system commands through that argument, and this can be done remotely over the network, though the attack requires high privileges on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:26Z"},"euvd":{"id":"EUVD-2024-33935","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/RURswTkepiuKCzkGMd2cA1M2nNc"]}