{"id":"CVE-2024-11659","published":"2024-11-25T06:31:24Z","modified":"2024-11-25T21:02:10Z","title":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_iperf command injection","vendor":"EnGenius","product":"ENH1350EXT","tier":"tail","description":{"text":"A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118 and classified as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_iperf. The manipulation of the argument iperf leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.15934,"percentile":0.97522,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.285980","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.285980","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.446642","tags":["third-party-advisory"]},{"url":"https://k9u7kv33ub.feishu.cn/wiki/OhR6w0THjiFeV1kSfZncaCxTn7f?from=from_copylink","tags":["exploit"]}],"priority":{"score":27.8,"factors":[{"name":"EPSS percentile","points":19.5},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"engenius","affectedVersions":[{"vendor":"EnGenius","product":"ENH1350EXT","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS500-AC","versions":["20241118"]},{"vendor":"EnGenius","product":"ENS620EXT","versions":["20241118"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2024-11-25T21:00:02.296123Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the diag_iperf functionality at /admin/network/diag_iperf in the EnGenius ENH1350EXT, ENS500-AC and ENS620EXT devices, where the iperf argument is not properly neutralised before use. An attacker with high-privilege access over the network can inject operating system commands through that argument, with no user interaction required.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:27Z"},"euvd":{"id":"EUVD-2024-33937","exploited":false,"provenance":"source"},"exploitRefs":["https://k9u7kv33ub.feishu.cn/wiki/OhR6w0THjiFeV1kSfZncaCxTn7f?from=from_copylink"]}