{"id":"CVE-2024-12372","published":"2024-12-18T15:28:25Z","modified":"2024-12-18T19:58:03Z","title":"Rockwell Automation PowerMonitor™ 1000 Denial of Service","vendor":"Rockwell Automation","product":"PM1k 1408-BC3A-485","tier":"tail","description":{"text":"A denial-of-service and possible remote code execution vulnerability exists in the Rockwell Automation Power Monitor 1000. The vulnerability results in corruption of the heap memory which may compromise the integrity of the system, potentially allowing for remote code execution or a denial-of-service attack.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.3,"severity":"CRITICAL","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00856,"percentile":0.5928,"provenance":"source"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html","tags":[]}],"priority":{"score":18.4,"factors":[{"name":"EPSS percentile","points":11.86},{"name":"CVSS severity","points":6.51}]},"vendorSlug":"rockwell-automation","affectedVersions":[{"vendor":"Rockwell Automation","product":"PM1k 1408-BC3A-485","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-BC3A-ENT","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-TS3A-485","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-TS3A-ENT","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-EM3A-485","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-EM3A-ENT","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-TR1A-485","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-TR2A-485","versions":["<v4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-EM1A-485","versions":["<4.020"]},{"vendor":"Rockwell Automation","product":"PM1k 1408-EM2A-485","versions":["<4.020"]}],"solutions":{"items":["Affected Products Affected firmware revision Corrected in firmware revision PM1k 1408-BC3A-485 <4.020 4.020 PM1k 1408-BC3A-ENT <4.020 4.020 PM1k 1408-TS3A-485 <4.020 4.020 PM1k 1408-TS3A-ENT <4.020 4.020 PM1k 1408-EM3A-485 <4.020 4.020 PM1k 1408-EM3A-ENT <4.020 4.020 PM1k 1408-TR1A-485 <4.020 4.020 PM1k 1408-TR2A-485 <4.020 4.020 PM1k 1408-EM1A-485 <4.020 4.020 PM1k 1408-EM2A-485 <4.020 4.020 PM1k 1408-TR1A-ENT <4.020 4.020 PM1k 1408-TR2A-ENT <4.020 4.020 PM1k 1408-EM1A-ENT <4.020 4.020 PM1k 1408-EM2A-ENT <4.020 4.020 Mitigations and Workarounds Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible. ·       Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-12-18T19:57:17.324443Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-50812","exploited":false,"provenance":"source"}}