{"id":"CVE-2024-23766","published":"2024-06-26T00:00:00Z","modified":"2025-03-13T18:29:11Z","title":"An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices","vendor":null,"product":null,"tier":"tail","description":{"text":"An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CISA ADP Vulnrichment"},"epss":{"score":0.00441,"percentile":0.39172,"provenance":"source"},"cwes":[{"id":"CWE-598","name":"Use of HTTP Request With Sensitive Query String"}],"references":[{"url":"https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/","tags":[]}],"priority":{"score":13.1,"factors":[{"name":"EPSS percentile","points":7.83},{"name":"CVSS severity","points":5.25}]},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2024-06-27T18:33:51.318160Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-21219","exploited":false,"provenance":"source"}}