{"id":"CVE-2024-2897","published":"2024-03-26T18:31:04Z","modified":"2024-08-01T19:25:42Z","title":"Tenda AC7 WriteFacMac formWriteFacMac os command injection","vendor":"Tenda","product":"AC7","tier":"tail","description":{"text":"A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0783,"percentile":0.94811,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"references":[{"url":"https://vuldb.com/?id.257940","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.257940","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.300360","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md","tags":["exploit"]}],"priority":{"score":28.4,"factors":[{"name":"EPSS percentile","points":18.96},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"tenda","affectedVersions":[{"vendor":"Tenda","product":"AC7","versions":["15.03.06.44"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2024-04-15T14:30:45.791519Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The Tenda AC7 router (firmware 15.03.06.44) has an OS command injection flaw in the formWriteFacMac function, reachable at /goform/WriteFacMac, where the mac argument is not properly sanitised. An attacker who can reach the device over the network and holds low-privilege credentials can inject operating system commands through that argument, with no user interaction required.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:18:32Z"},"euvd":{"id":"EUVD-2024-27841","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md"]}