{"id":"CVE-2024-32870","published":"2024-11-04T23:36:46Z","modified":"2024-11-05T16:26:44Z","title":"iTop hub connector Information disclosure","vendor":"Combodo","product":"iTop","tier":"core","eol":null,"affectedVersions":[{"vendor":"Combodo","product":"iTop","versions":["< 2.7.11",">= 3.0.0, < 3.0.5",">= 3.1.0, < 3.1.2"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2024-11-05T16:25:00.433322Z","from":"CISA ADP","provenance":"source"},"description":{"text":"Combodo iTop is a simple, web based IT Service Management tool. Server, OS, DBMS, PHP, and iTop info (name, version and parameters) can be read by anyone having access to iTop URI. This issue has been patched in versions 2.7.11, 3.0.5, 3.1.2, and 3.2.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.","provenance":"source","from":"CVE.org"},"summary":null,"cvss":{"score":5.8,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00751,"percentile":0.55898,"date":"2026-11-20","provenance":"source"},"kev":null,"vulncheckKev":{"dateAdded":"2025-06-08","exploitedFirstSeen":"2025-06-08","ransomware":false,"evidence":[{"url":"https://app.crowdsec.net/cti/cve-explorer/CVE-2024-32870","date":"2025-06-08"}],"evidenceTotal":1,"provenance":"source"},"exploited":true,"otx":{"pulseCount":0,"pulses":[],"provenance":"machine"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"references":[{"url":"https://github.com/Combodo/iTop/security/advisories/GHSA-rfjh-2f5x-qxmx","tags":["x_refsource_CONFIRM"]}],"techniques":[],"reports":[],"affected":[],"advisories":[],"euvd":{"id":"EUVD-2024-30653","url":"https://euvd.enisa.europa.eu/vulnerability/EUVD-2024-30653","exploited":false,"exploitedSince":null,"provenance":"source"},"exploits":[],"exploitSources":{"nuclei":[{"id":"CVE-2024-32870","name":"iTop Hub Connector - Information Disclosure","severity":"medium","path":"http/cves/2024/CVE-2024-32870.yaml","url":"https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-32870.yaml"}],"provenance":"source"},"exploitRefs":[],"flow":[],"timeline":[{"date":"2024-11-04","kind":"published","label":"Published (CVE.org)","url":"https://www.cve.org/CVERecord?id=CVE-2024-32870","provenance":"source"},{"date":"2025-06-08","kind":"exploited-reported","label":"Exploitation first reported (VulnCheck KEV evidence)","url":"https://app.crowdsec.net/cti/cve-explorer/CVE-2024-32870","provenance":"source"}],"speed":{"daysToPublicExploit":null,"firstExploitFrom":null,"daysToKev":null},"priority":{"score":55.2,"factors":[{"name":"In a KEV catalog","points":35.0,"detail":"listed in VulnCheck KEV"},{"name":"Recent KEV listing","points":0.0,"detail":"added 531 days ago"},{"name":"Known ransomware use","points":0.0,"detail":"not known"},{"name":"EPSS percentile","points":11.18,"detail":"percentile 0.5590"},{"name":"Named in threat reports","points":0.0,"detail":"0 reports"},{"name":"Public exploit code","points":5.0,"detail":"1 nuclei template"},{"name":"Mentioned in OTX pulses","points":0.0,"detail":"0 pulses"},{"name":"CVSS severity","points":4.06,"detail":"base score 5.8"},{"name":"End-of-life product","points":0.0,"detail":"supported or unknown"}]}}